--- title: "system.util.execute" description: "Executes the given commands via the operating system, in a separate process." --- # system.util.execute > Executes the given commands via the operating system, in a separate process. This function is used in **Python Scripting**. ## Description Executes the given commands via the operating system, in a separate process. The commands argument is an array of strings. The first string is the program to execute, with subsequent strings being the arguments to that command. ## Client Permission Restrictions This scripting function has no [Client Permission](projects\project-properties\project-properties.md#client---permissions) restrictions. ## Syntax `system.util.execute(commands)` ### Parameters |Type|Parameter|Description| |--|--|--| |String[]| `commands` | A list containing the command (1st entry) and associated arguments (remaining entries) to execute.| ### Returns Nothing ### Scope All ## Code Examples ```python title="Example #1" # This code starts the Firefox browser and opens the Google home page. system.util.execute(['C:\\Program Files\\Mozilla Firefox\\firefox.exe', 'https://www.google.com']) ``` ```python title="Example #2" # This function flushes the resolver cache. system.util.execute(["ipconfig", "/flushdns"]) ``` ```python title="Example #3" # This code runs the Notepad program and opens the Ignition license text file. system.util.execute(['notepad.exe', 'c:\\program files\\inductive automation\\ignition\\license.txt']) ```