--- title: "getBit" description: "This function returns the bit value (an integer, 0 or 1) in the number at position position, according to its binary representation." --- # getBit > This function returns the bit value (an integer, 0 or 1) in the number at position position, according to its binary representation. **This function is used by Ignition's Expression language.** ## Description This function returns the bit value (an integer, 0 or 1) in the number at position position, according to its binary representation. The least significant bit in a number is position 0. ## Syntax `getBit(number, position)` - Parameters - int **number** - The number value to start with. - int **position** - The bit position to check. - Results - int - A 0 or 1, depending on the bit at the position of the integer specified. ## Examples ```python title="Code Snippet" getBit(0,0) //would return 0 ``` ```python title="Code Snippet" getBit(1,0) //would return 1 ``` ```python title="Code Snippet" getBit(8,2) //would return 0 ```