--- title: "Meter" description: "A meter display shows a value on a needle-gauge. " --- # Meter > A meter display shows a value on a needle-gauge. ![](Meter0.png) **Component Palette Icon** ![](Meter1.png) A meter display shows a value on a needle-gauge. The gauge's range can be broken up into five intervals. The intervals can have their own edge and background colors.How the meter looks is affected by its appearance properties. You can modify colors, thicknesses, start and extend angles, needle size, etc to get the meter that you want. For example, the meter on the far right of the example has a Meter Angle Extent of 90°, a Meter Angle of 45°, a reversed range, and 2 intervals. ## Properties |Name|Description|Property Type|Scripting|Category| |:---|:---|:---|:---|:---| |Arc Width|The width of the colored interval arcs.|float|.arcWidth|Appearance| |Border|The border surrounding this component. NOTE that the border is unaffected by rotation.|Border|.border|Common| |Cursor|The mouse cursor to use when hovering over this component.|int|.cursorCode|Common| |Data Quality|The data quality code for any tag bindings on this component.|int|.dataQuality|Data| |Dial Background|The background color of the dial face.|Color|.dialBackground|Appearance| |Dial Shape|The shape of the dial. This property determines how the dial face looks in the area not covered by the meter angle extent.|int|.dialType|Appearance| |Interval 1 Background|The color to fill the wedge of this interval.|Color|.interval1Background|Intervals| |Interval 1 High|The upper bound of this interval.|double|.interval1High|Intervals| |Interval 1 Low|The lower bound of this interval.|double|.interval1Low|Intervals| |Interval 1 Outline|The color to paint the arc of this interval.|Color|.interval1Outline|Intervals| |Interval 2 Background|The color to fill the wedge of this interval.|Color|.interval2Background|Intervals| |Interval 2 High|The upper bound of this interval.|double|.interval2High|Intervals| |Interval 2 Low|The lower bound of this interval.|double|.interval2Low|Intervals| |Interval 2 Outline|The color to paint the arc of this interval.|Color|.interval2Outline|Intervals| |Interval 3 Background|The color to fill the wedge of this interval.|Color|.interval3Background|Intervals| |Interval 3 High|The upper bound of this interval.|double|.interval3High|Intervals| |Interval 3 Low|The lower bound of this interval.|double|.interval3Low|Intervals| |Interval 3 Outline|The color to paint the arc of this interval.|Color|.interval3Outline|Intervals| |Interval 4 Background|The color to fill the wedge of this interval.|Color|.interval4Background|Intervals| |Interval 4 High|The upper bound of this interval.|double|.interval4High|Intervals| |Interval 4 Low|The lower bound of this interval.|double|.interval4Low|Intervals| |Interval 4 Outline|The color to paint the arc of this interval.|Color|.interval4Outline|Intervals| |Interval 5 Background|The color to fill the wedge of this interval.|Color|.interval5Background|Intervals| |Interval 5 High|The upper bound of this interval.|double|.interval5High|Intervals| |Interval 5 Low|The lower bound of this interval.|double|.interval5Low|Intervals| |Interval 5 Outline|The color to paint the arc of this interval.|Color|.interval5Outline|Intervals| |Meter Angle|The angle in degrees of the centerpoint of the meter (90 is straight up).|int|.meterAngle|Appearance| |Meter Angle Extent|The extent, in degrees, of the entire meter.|int|.meterAngleExtent|Appearance| |Mouseover Text|The text that is displayed in the tooltip which pops up on mouseover of this component.|String|.toolTipText|Common| |Name|The name of this component.|String|.name|Common| |Needle Color|The color of the meter's needle.|Color|.needleColor|Appearance| |Needle Size|The size of the base of the needle.|float|.needleSize|Appearance| |Needle Stroke Color|The color of the needle's stroke.|Color|.needleStrokeColor|Appearance| |Needle Stroke Size|The size of the needle's stroke.|float|.needleStrokeSize|Appearance| |Overall High Bound|The high bound for the whole meter.|double|.overallHigh|Data| |Overall Low Bound|The lower bound for the whole meter.|double|.overallLow|Data| |Reverse Range?|If true, the meter will consider right to left needle movement as positive.|boolean|.reverseRange|Data| |Show Tick Labels?|If true, value will be shown on interval-boundary ticks.|boolean|.ticks|Appearance| |Styles|Contains the component's styles.|Dataset|.styles|Appearance| |Tick Color|The color of tick marks.|Color|.tickColor|Appearance| |Tick Format|The number format to use for the tick labels.|String|.tickLabelFormat|Appearance| |Tick Label Color|The color of the tick labels.|Color|.tickLabelColor|Appearance| |Tick Label Font|The font to use for the tick labels.|Font|.labelFont|Appearance| |Tick Size|The distance between ticks.|double|.tickSize|Appearance| |Units|A string to describe the units for the current value label.|String|.units|Appearance| |Value|The value to display in this meter. The needle and current value label will change to reflect this.|double|.value|Data| |Value Color|The color of the meter's current value label.|Color|.valueColor|Appearance| |Value Format|The number format to use for the value label.|String|.valueLabelFormat|Appearance| |Value Label Font|The font to use for the current value label.|Font|.valueFont|Appearance| |Visible|If disabled, the component will be hidden.|boolean|.visible|Common| ## Scripting ### Scripting Functions This component does not have scripting functions associated with it. ### Extension Functions This component does not have extension functions associated with it. ### Event Handlers Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the [Component Events](scripting\scripting-in-ignition\component-and-window-scripting\component-events.md) page ## Customizers + [Vision Component Customizers](visualization-and-dashboards\understanding-components\component-customizers\component-customizers.md) + [Style Customizer](visualization-and-dashboards\understanding-components\component-customizers\component-customizers.md#style-customizer) ## Examples #### Updated Fonts ![](Meter2.png) |Property Name|Value| |:---|:---| |Value|35| |Unit|m/s| |Value Label Font|Vijaya, Bold, 15| |Tick Label Font|Vijaya, Bold, 15| #### Chord Meter with Modified Value Intervals ![](Meter3.png) |Property Name|Value| |:---|:---| |Value|35| |Reverse Range?|True| |Units|'None'| |Arc Width|10| |Meter Angle Extent|220| |Meter Angle|0| |Dial Shape|Chord| |Interval 1 Low|40| |Interval 2 High|60| |Interval 3 Low|70|