New in this Version π£
Over the course of development, naturally there are changes and additions to the Ignition software. This page highlights any new functionality or modified behavior, but is not meant as a complete resource for new features. You can find more about these items by following the links on this page.
Determining Your Current Versionβ
The current version of Ignition can be viewed by visiting the Welcome page of the Gateway.
-
Navigate to your Gateway and select the Home tab to view the Welcome page.
-
Locate the Gateway Version under the Gateway Overview section on the Welcome page.
noteYou must be logged in with Read or Write Permissions to see this section. If you aren't prompted to log in, you can select the Log In option in the upper right-hand corner of the screen.

Upgrading Ignitionβ
Upgrading Ignition is easy, but there are a few things we recommend to ensure everything goes smoothly.
See the Installing and Upgrading page for a complete guide.
New Ignition Perspective Mobile App Featuresβ
This section is devoted to new features introduced to the Ignition Perspective Mobile App. New versions of the app are released separately from new Ignition versions, so notable changes to the app will be listed in this section.
New Ignition Featuresβ
This section is devoted to new features introduced to Ignition. Any pages in this user manual that contain features that were added will be accompanied by a display like this:
New in 2027.02β
Catalystβ
- The Catalyst Core and Catalyst Agent modules are now available.
Enterprise Administration Module (EAM)β
- Controllers can now assign a single leased license key to multiple agents if support for multiple sessions is available.
- Added a Controller Operations page to the Gateway to allow controllers to send changeset files to other controllers and agents.
Event Streamsβ
- The OPC UA Event source is now available to use.
Expressionsβ
- Users can now use negative subscripts to access elements at a specific index in datasets, lists, and arrays.
Gatewayβ
- Updated singleton resources to display the immutable configurations with all fields and buttons disabled.
- Updated resource descriptions and enabled state to apply to the resource as a whole. Both are now shared by the Primary and Backup versions of a resource and are changed through the three dots menu instead of the Edit panel.
Historianβ
- Added an Enterprise Historian module, which delivers the Enterprise Historian provider, to improve time-series data storage and management for large Ignition systems.
Installers and Launchersβ
- Improved the Windows installer's handling of command line arguments.
Localizationβ
- Rebuilt the Translation Manager in the Designer. Translation keys can now include notes that describe their context, and multiple keys can be added at once with Batch Entry.
- Improved the performance of translation lookups on the Gateway.
- Added the ability to import and export Gateway translations in two new formats: a zip of JSON files or an Excel (.xlsx) file.
OPC UAβ
- Added an OPC UA Redundant connection type that connects to a redundant set of OPC UA servers using OPC UA non-transparent redundancy. The connection discovers every server in the set, monitors each server's Service Level, and fails over automatically in Cold, Warm, or Hot mode.
- Renamed the View Details option for OPC connections to Diagnostics.
Perspectiveβ
- Updated the Power Chart component to improve usability and customization options, including a refined X Trace display, a Pen Control Quality column, and a chart loading indicator.
- Added a Radar component to chart palette that compares multiple values across several dimensions simultaneously.
- Added a built-in on-screen keyboard. You can create, import, export, and preview keyboard layouts in the Designer using Tools > Workstation Keyboard Layouts.
- Updated the Pie Chart component to improve usability and appearance, including new variants and Component Events.
- Updated the Gauge component with new basic, threshold, and setpoint variants.
- Added a dedicated Line component to chart palette that compares series of data points against time or value axes.
- Added a dedicated Bar component to the chart palette.
- Added an Area component to chart palette that communicates volume or magnitude in addition to trend direction.
- Added a Heatmap component that visualizes magnitude across two categorical or temporal dimensions simultaneously.
Redundancyβ
- Added a Zero Data Loss functionality that enables backup Gateways to capture and retain historian data during standby, then automatically backfill the historian data to eliminate data loss windows.
Reportingβ
- Added an SVG component to the Report Design tab interface.
Scriptingβ
- Added a
getChildrenparameter for the system.tag.getConfiguration() and system.tag.query() scripting functions. - Added the system.i18n scripting namespace with new functions for working with localization.
Securityβ
- Added the option to select a target collection for a duplicated key on the API Key settings page.
Transaction Groupsβ
- Added the ability to open multiple Transaction Group tabs simultaneously, matching functionality with the Named Query and Reporting Designer interfaces.