Vision - Easy Chart Scripting Functions

Scripting Functions​

exportExcel(filename)​

  • Description

    • This function saves the chart's datasets as an Excel file. Returns a String of the complete file path chosen by the user, or None if the user canceled the save.
  • Parameters

    • String filename - The default file name for the Save dialog.
  • Return

    • String

print()​

  • Description

    • This function will print the chart.
  • Parameters

    • None
  • Return

    • None

setMode(mode)​

  • Description

    • Sets the current mode for the chart.
  • Parameters

    • Integer mode - The mode to set the chart to. The mode options are as follows:

      • 0 : Zoom Mode. This is the default mode, where the user can draw a zoom rectangle with the mouse pointer.

      • 1 : Pan Mode. This mode lets the user use the mouse pointer to pan the chart to the left and right.

      • 3 : Mark mode. This mode lets the user click near a datapoint to annotate the point with its X and Y value.

      • 4 : X-Trace mode. This mode lets the user click and drag on the chart to see all values that fall along that X value.

  • Return

    • None

exportDatasets()​

  • Description

    • Returns an Array List of datasets, representing the time series data of each type of pen.
  • Parameters

    • None
  • Return

    • Array List of datasets. Each dataset represents timeseries data for set of pens. The order of the datasets are listed below.

Index order of datasets​

IndexDataset
0Tag Pens
1Calculated Pens
2Database Pens
Python - Accessing the Tag Pens Dataset
# This example extracts the Easy Chart's Tag Pens dataset and pushes it to a Power Table.
# Place this script on the Easy Chart's propertyChange event.

if event.propertyName == 'tagPens':
# Capture references up front.
# This is safer than using `event` directly inside the delayed call,
# since by the time the function executes, the event object may no longer be valid.
chart = event.source
table = chart.parent.getComponent('Power Table')

# Wrap our dataset behavior in a function so we can pass it to invokeLater
def update_table():
# Export datasets; index 0 contains Tag Pens series data
datasets = chart.exportDatasets()
table.data = datasets[0]

# Delay until after the chart finishes loading the new tag
system.vision.invokeLater(update_table, 1000)

Extension Functions​

configureChart​

  • Description

    • Provides an opportunity to perform further chart configuration via scripting. Doesn't return anything.
  • Parameters

    • Component self - A reference to the component that is invoking this function.

    • JFreeChart chart - A JFreeChart object. Refer to the JFreeChart documentation for API details.

  • Return

    • None

getXTraceLabel​

  • Description

    • Provides an opportunity to configure the x-trace label. Return a string to override the default label.
  • Parameters

    • Component self - A reference to the component that is invoking this function.

    • JFreeChart chart - A JFreeChart object. Refer to the JFreeChart documentation for API details.

    • String penName - The name of the pen the x-trace label applies to.

    • Integer yValue - The y-value of the pen at the x-trace location.

  • Return

    • None

onPowerTableRowsDropped​

  • Description

    • Called when the user has dropped rows from a power table on the chart. The source table must have dragging enabled.
  • Parameters

    • Component self - A reference to the component that is invoking this function.

    • Component sourceTable - A reference to the table that the rows were dragged from.

    • List rows - An array of the row indicies that were dragged, in the order they were selected.

    • Dataset rowData - A dataset containing the rows that were dragged.

  • Return

    • None

onTagsDropped​

  • Description

    • Called when the user has dropped tags from the tag tree onto the chart. Normally, the chart will add pens automatically when tags are dropped, but this default behavior will be suppressed if this extension function is implemented.
  • Parameters

    • Component self - A reference to the component that is invoking this function.

    • List paths - A list of the tag paths that were dropped on the chart.

  • Return

    • None
Example - Pen Name Replacement
# This will take a tag that gets dropped from a Tag Browse Tree set in Realtime Tag Tree mode,
# and will replace the underscores in the name of the tag "_" and replace them with spaces.
tagPens = self.tagPens

for tag in paths:
tagPath = tag.replace("default", "~")
splitTag = tag.split("/")
name = splitTag[-1].replace("_", " ")

newRow = [name, tagPath, "MinMax", "Default Axis", 1, 1, system.vision.color(255, 85, 85, 255), "", 1, 1, 0, 1, 0, "", 0, 0, 0, 1, 0, 0]

self.tagPens = system.dataset.addRow(tagPens, newRow)
Example - Group Name
# This will take a tag that gets dropped from a Tag Browse Tree set in Realtime Tag Tree mode,
# and will place it into a Pen Group titled "My Group Name".

tagPens = self.tagPens
groupName = "My Group Name"
for tag in paths:

newRow = [name, tagPath, "MinMax", "Default Axis", 1, 1, system.vision.color(255, 85, 85, 255), "", 1, 1, 0, 1, 0, groupName, 0, 0, 0, 1, 0, 0]

self.tagPens = system.dataset.addRow(tagPens, newRow)