Vision - Radio Button

Component Palette Icon:

The Radio Button is similar to the CheckBox component, except for one special property. All Radio Buttons in the same Container (including the Root Container) will automatically be mutually exclusive. This means that only one Radio Button can be selected at a time. Radio Buttons are a good way to let the user choose just one of a number of options. Dropdown Lists are another good way to do this.

Properties​

PropertyDescriptionProperty TypeScriptingCategory
Background ColorThe background color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.backgroundAppearance
BorderThe border surrounding this component. Options are No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), and Field Border.
Note: The border is unaffected by rotation.
Border.borderCommon
CursorThe mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize.int.cursorCodeCommon
EnabledIf disabled, a component cannot be used.boolean.componentEnabledCommon
Fill BackgroundIf true, the label's background color will be drawn. If false, it will have a transparent background.boolean.fillBackgroundAppearance
FocusableIf a button is not focusable, you will not be able to interact with it with the keyboard. This means you can't "tab" over to it.boolean.focusableBehavior
FontFont of text on this component.Font.fontAppearance
Foreground ColorThe foreground color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.foregroundAppearance
Horizontal AlignmentThe horizontal alignment of the button's contents (text and/or image).int.horizontalAlignmentLayout
MarginThe internal margin that provides padding for the contents of this button.Insets.marginAppearance
Mouseover TextThe text that is displayed in the tooltip which pops up on mouseover of this component.String.toolTipTextCommon
NameThe name of this component.String.nameCommon
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
RolloverIf true, the button may indicate that the mouse is hovering over it.boolean.rolloverEnabledBehavior
SelectedThe current state of the Radio Button.boolean.selectedData
StylesContains the component's styles.Dataset.stylesAppearance
TextText of this component.String.textAppearance
Vertical AlignmentThe vertical alignment of the button's contents (text and/or image).int.verticalAlignmentLayout
VisibleIf disabled, the component will be hidden.boolean.visibleCommon

Deprecated Properties​

PropertyDescriptionProperty TypeScriptingCategory
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated

Scripting​

Component Functions​

This component does not have component functions associated with it.

Extension Functions​

This component does not have extension functions associated with it.

Event Handlers​

Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the Component Events page

Customizers​

Example​

Radio Buttons inside a container will be exclusive therefore selecting one Radio Button will de-select the other Radio Buttons.