Skip to main content
Version: 2027.02 Beta
View as Markdown

Report - SVG

The SVG component allows .svg image files to be placed, resized, and copy and pasted onto report pages. SVGs can be dragged from a local computer, shared drive, or the Image Management Tool onto reports. These files will fill an existing SVG component or be displayed in an SVG component when first added to a page. Other image file types will be contained in an Image component.

The placeholder image for an SVG component added to a report page.

Report Design Component

The SVG component icon shown in the Report Components panel.

Properties​

Use the SVG properties in the Property Inspector to configure the SVG component.

Stroke and Fill​

PropertyDescription
OpacityHow opaque the fill color is, between 0 and 1.
Stroke StyleWhat style of stroke or border to use, options include:
  • Hidden
  • Shape Outline
  • Border
  • Double
To learn more about stroke styles, refer to the Stroke and Fill Properties page.
StrokeDetails for the chosen stroke. Each Stroke has its own properties depending on the Stroke Style chosen.

Basic Properties​

PropertyDescription
RollThe number of degrees this shape is rotated clockwise. Default is 0.
Scale XThe amount to scale the width of the shape. A value of 1 results in scaling to 100 percent. Default is 1.
Scale YThe amount to scale the height of the shape. A value of 1 results in scaling to 100 percent. Default is 1.
URLA link to attach to this shape. It will be a clickable hyperlink if the report is exported as a PDF. Links can also be configured for internal navigation using the following values:
  • Page:Next: Navigates to the next page.
  • Page:Back: Navigates to the previous page.
  • Page:Number: Replace Number with the specific page number to navigate to.
VisibleIf true, the shape will be visible. Default is true.
WidthThe width of the shape in pixels. Default is 160.
HeightThe height of the shape in pixels. Default is 100.
XThe horizontal distance in pixels between the left edge of this shape and the left edge of the page.
YThe vertical distance in pixels between the upper edge of this shape and the top edge of the page.

Graphics​

PropertyDescription
Use RasterIf true, the component is displayed as a raster image. If false, the component is displayed as a vector. Default is false.

Example​

The example below shows the property changes applied to a sample-images/flags/ SVG dragged from the Image Management tool onto a report page.

The Norwegian flag centered at the top of a report page.

PropertyValue
Stroke StyleHidden
Width300
Height220
X160
Y60