Perspective - Equipment Schedule Scripting
This page details the component-specific events and functions available for Perspective's Equipment Schedule component. Right-click on the component or select Components from the Designer menubar to access the Configure Events and Configure Scripts popups.
Component Events​
The Perspective Event Types Reference page describes all the possible component event types for Perspective components.
onAddEvent​
Event is fired after a user adds an event to the schedule.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.end​
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the new event.
event.itemId​
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was created.
event.start​
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the new event.
from random import random, randint
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
r = random() * 255
g = random() * 255
b = random() * 255
color = "rgb(" + str(r) + "," + str(g) + "," + str(b) + ")"
percentDone = randint(0, 100)
leadTime = randint(300, 6000)
item = {
"endDate": system.date.parse(event.end, format, locale),
"itemId": event.itemId,
"startDate": system.date.parse(event.start, format, locale),
"eventId": "event_" + str(randint(1000, 10000)),
"backgroundColor": color,
"percentDone": percentDone,
"leadTime": leadTime
}
scheduled.append(item)
onMoveEvent​
Event is fired after a user moves an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.end​
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The new end date of the moved event.
event.eventId​
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the moved event.
event.itemId​
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was moved.
event.start​
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The new start date of the moved event.
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and event.itemId == toFind.itemId:
toFind.startDate = system.date.parse(event.start, format, locale)
toFind.endDate = system.date.parse(event.end, format, locale)
onResizeEvent​
Event is fired after a user resizes an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.end​
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The new end date of the resized event.
event.eventId​
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the resized event.
event.itemId​
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was resized.
event.start​
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The new start date of the resized event.
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
scheduled = self.props.scheduledEvents
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and event.itemId == toFind.itemId:
toFind.startDate = system.date.parse(event.start, format, locale)
toFind.endDate = system.date.parse(event.end, format, locale)
onDeleteEvent​
Event is fired after a user deletes an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.end​
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the deleted event.
event.eventId​
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the deleted event.
event.itemId​
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was deleted.
event.start​
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the deleted event.
scheduled = self.props.scheduledEvents
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and toFind.itemId == event.itemId:
del scheduled[count]
break
onClickEvent​
Event is fired after a user clicks on an event.
This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.
event.end​
-
Object Path
- event.end
-
Type
- Integer or float
-
Description
- The end date of the clicked event.
event.eventId​
-
Object Path
- event.eventId
-
Type
- String, integer, or float
-
Description
- The event identifier of the clicked event.
event.itemId​
-
Object Path
- event.itemId
-
Type
- String, integer, or float
-
Description
- The item identifier where this event was clicked.
event.start​
-
Object Path
- event.start
-
Type
- Integer or float
-
Description
- The start date of the clicked event.
scheduled = self.props.scheduledEvents
format = "yyyy-MM-dd HH:mm:ss z"
locale = "en-us"
for count, toFind in enumerate(scheduled):
if toFind.eventId == event.eventId and toFind.itemId == event.itemId:
print scheduled[count]
break
Component Functions​
This component does not have component functions associated with it.
Extension Functions​