User Manual

GETTING STARTED


OTHER EDITIONS


LAUNCHERS


MODULES


PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support

ALL USER MANUAL VERSIONS

Ignition 8.1. Offline Version (04/2021)
Ignition 8 Online Version
Ignition 7.9 Online Version
Ignition 7.8 Online Version

Deprecated Pages

SDK Documentation

Employees

Sign In

Skip to end of metadata
Go to start of metadata

This function is used in Python Scripting.

Description

Returns the Ignition version number that is currently being run.

Note: If the version is from a nightly build or developer version that is not yet released, the version number will come back as "Dev Version", for example:


Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.util.getVersion()

  • Parameters

Nothing

  • Returns

Version - The currently running Ignition version number, as a Version object.

  • Scope

Gateway, Vision Client, Perspective Session

This section documents available attributes on the object.

Method and/or AttributeDescriptionReturn type
.major

Returns only the major version number.

8.0.2 returns 8

Integer
.minor

Returns only the minor version number.

8.0.2 returns 0

Integer
isFutureVersion()

Takes in a string version number and returns whether the current version is greater than the given version (true or false). Note: this does account for Snapshot, RC or Beta versions.

Version format expected: "X.X.X" ie "8.0.7" See example below.

Boolean
Code Examples
Code Snippet
# This code displays the name of the currently running Ignition version number.
system.gui.messageBox("You are running project: %s" % system.util.getVersion())
Code Snippet
# This code displays whether a given version is older than the current version.
currentVersion = system.util.getVersion()
testVersion = "8.0.7"
isFuture = currentVersion.isFutureVersion(testVersion)
print "Your version (%s) is older than %s: %s" %(currentVersion, testVersion, isFuture) 
Keywords