This function is used in Python Scripting.

Description

Allows for invoking system.gui functions on a specific desktop. See the Multi-Monitor Clients page for more details.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.gui.desktop(handle)

  • Parameters

String handle The handle for the desktop to use. The screen index cast as a string may be used instead of the handle. If omitted, this will default to the primary desktop. Alternatively, the handle "primary" can be used to refer to the primary desktop.

  • Returns

WindowUtilities -  A copy of system.gui (WindowUtilities) that will be relative to the desktop named by the given handle.  

  • Scope

Vision Client

Code Examples
Code Snippet - Opening Message Box in a Different Desktop
# The following example makes a message box appear on the primary desktop, 
# regardless of where the script originates. 
# system.gui.desktop() function requires a handle be passed to it for this example 
# to work properly.
system.gui.desktop().messageBox("This will appear on the Primary Desktop")
Code Snippet - Showing Open Windows in a Specific Desktop
# Retrieves a list of open windows in a specific Desktop. This example assumes a desktop with the handle "2nd Desktop" exists. 
name = "2nd Desktop"
# Returns a tuple of open windows in the Desktop named "2nd Desktop".
windows = system.gui.desktop(name).getOpenedWindows()

# Converts the tuple to a string, and shows the items in a message box.
system.gui.messageBox(str(windows))
Keywords

system gui desktop, gui.desktop