This function is used in Python Scripting.

Description

This function converts from a normal dataset to a PyDataset, which is a wrapper class which makes working with datasets more Python-esque. For more information on datasets and PyDatasets, see the Datasets page. 

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.dataset.toPyDataSet(dataset)

  • Parameters

Dataset dataset - A dataset object to convert into a PyDataset.

  • Returns

PyDataset - The newly created PyDataset.

  • Scope

Gateway, Vision Client, Perspective Session

Code Examples
Code Snippet - Summing Values in a Column
# This example script would be added to a button that is in the same container as the table you are working with. 
# It grabs the data of the Table component, and adds up the values in the first column, displaying the result to the user.
 
# Get a Table component's data.
table = event.source.parent.getComponent("Table")
data = system.dataset.toPyDataSet(table.data)
 
# Loop through the data, summing the Value column.
value = 0.0
for row in data:
   value += row[0]
 
# Show the user the sum of the Value column.
system.gui.messageBox("The value is: %f" % value)
Keywords

system dataset toPyDataSet, dataset.toPyDataSet