This function is used in Python Scripting.

Description

Takes a dataset and returns a new dataset with one value altered.

Note: Datasets are immutable, which means they cannot be directly modified once created. Instead, this scripting function returns a new dataset with some modification applied, which must be assigned to a variable to be used. See Altering a Dataset.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.dataset.setValue(dataset, rowIndex, columnName, value)

  • Parameters

Dataset dataset - The starting dataset. Will not be modified (datasets are immutable), but acts as the basis for the returned dataset.

Integer rowIndex - The index of the row to set the value at (starting at 0).

String columnName - The name of the column to set the value at. Case insensitive.

Any value - The new value for the specified row/column.

  • Returns

Dataset - A new dataset, with the new value set at the given location.

  • Scope

Gateway, Vision Client, Perspective Session

Syntax

system.dataset.setValue(dataset, rowIndex, columnIndex, value)

  • Parameters

Dataset dataset - The starting dataset. Will not be modified (datasets are immutable), but acts as the basis for the returned dataset.

Integer rowIndex - The index of the row to set the value at (starting at 0).

Integer columnIndex - The index of the column to set the value at (starting at 0)

Any value - The new value for the specified row/column.

  • Returns

Dataset - A new dataset, with the new value set at the given location.

  • Scope

Gateway, Vision Client, Perspective Session

Code Examples
Code Snippet
# This snippet demonstrates how to take an initial dataset, set a new value on a new dataset, and then write back to the source of the initial dataset. 
# In this case we're using a Table component from the Vision module. 
# Fetch a reference to an existing dataset. 
table = event.source.parent.getComponent("Table")

# Make a new dataset with an updated value
newData = system.dataset.setValue(table.data, 3, "lname", 7)

# Repalce the table's dataset with our new dataset
table.data = newData

Code Snippet
# This snippet could be used for a Vision Button's actionPerformed event to change the selected cell's value in a Table component to zero.
# Fetch table reference
table = event.source.parent.getComponent("Table")

# Fetch selected row and column
selRow = table.getSelectedRow()
selCol = table.getSelectedColumn()

# If row and column have been selected, update value in table to 0.
if selRow != -1 and selCol != -1:
   newData = system.dataset.setValue(table.data, selRow, selCol, 0.0)
   table.data = newData
Keywords

system dataset setValue, dataset.setValue