This button component will toggle a value between two states, such as On/Off, Stop/Run, etc. To toggle between more than two states, use the Multi-State Button. 

NameDescriptionProperty TypeScriptingCategory
Background ColorThe background color of the button. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector . Color.buttonBGAppearance
Border

The border surrounding this component. No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

Note: The border is unaffected by rotation.

Border.borderCommon
Border Painted?

Indicates if the border of this button will be displayed.

Note: This property was removed in 8.1.8

boolean.borderPaintedAppearance
Confirm TextThe message displayed in the confirmation box if Confirm? is true.String.confirmTextBehavior
Confirm?If true, a confirmation box will be shown.boolean.confirmBehavior
Control ValueBind this to the tag that controls the state. (Typically, this is bound to the same location as Indicator Value).int.controlValueData
Current StateRead-only property that shows the button's current state (0 or 1)int.stateData
CursorThe mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize.int.cursorCodeCommon
Disabled Image PathThe relative path of the image to be displayed when this component is not enabled.String.disabledPathAppearance
EnabledIf disabled, a component cannot be used.boolean.componentEnabledCommon
Fill Area?Controls whether or not this button's internal area is filled.boolean.contentAreaFilledAppearance
FocusableIf a button is not focusable, you will not be able to interact with it with the keyboard.boolean.focusableBehavior
FontFont of text on this component.Font.fontAppearance
Foreground ColorThe foreground color of the component. See Color Selector. Color.foregroundAppearance
Horizontal AlignmentThe horizontal alignment of the button's contents (text and/or image)int.horizontalAlignmentLayout
Horizontal Text PositionThe horizontal position of the button's text relative to its image.int.horizontalTextPositionLayout
Icon-Text SpacingThe space (in pixels) between the icon (if any) and the text (if any).int.iconTextGapAppearance
Image PathThe relative path of the image.String.pathAppearance
Indicator ValueBind this to the tag that indicates the current state. (If you don't have separate tags for status and control, this is bound to the same location as Control Value)int.indicatorValueData
MarginThe space between a button's text and its borders.Insets.marginLayout
MnemonicA single letter that will activate the button using 'ALT-mnemonic'.String.mnemonicCharBehavior
Mouseover TextThe text that is displayed in the tooltip which pops up on mouseover of this component.String.toolTipTextCommon
NameThe name of this component.String.nameCommon
Opaque

If true, button will be opaque. Default is false.

Note: This property was removed in 8.0.0

boolean.opaqueDeprecated
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
RolloverIf true, the button may indicate that the mouse is hovering over it.boolean.rolloverEnabledBehavior
State 1 ValueThe value that will be written to controlValue when the button is pushed in state 2.int.state1ValueData
State 2 ValueThe value that will be written to controlValue when the button is pushed in state 1.int.state2ValueData
StylesContains the component's styles.Dataset.stylesAppearance
TextText of this component.String.textAppearance
Vertical AlignmentThe vertical alignment of the button's contents (text and/or image).int.verticalAlignmentLayout
Vertical Text PositionThe vertical position of the button's text relative to its image.int.verticalTextPositionLayout
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
Deprecated Properties
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated

Scripting

Component Functions

This component does not have component functions associated with it.

Extension Functions

This component does not have extension functions associated with it.

Examples

2-State Toggle with Styles Configured

Property NameDataset
Styles