Row Properties | Name | Description | Category |
---|
| Structured Columns | If true, this row will be organized into columns, otherwise, the row will allow free form design. | Table Row |
Column Count | If this row is structured, this is the number of columns in the row. | Table Row |
Move to Bottom | If true, this row will be moved to the bottom of the table. | Table Row |
Print Empty Group | If true, row will print even if it has no children. Only applicable for header or summary rows. | Table Row |
Sync Alternate Versions | If checked, the columns widths of this row will be synchronized with alternate row versions. | Table Row |
Sync Row Above | If checked, the column widths of this row and the row above it will be synchronized as long as they have the same number of fields. | Table Row |
Version Key | Data Key to drive which version of the table row to display. | Table Row |
Fill | If true, the shape will fill its space with color. | Stroke and Fill |
Fill Color | If Fill is selected, the color that will fill the shape. | Stroke and Fill |
Opacity | How opaque the fill color is, between 0 and 1. | Stroke and Fill |
Stroke Style | What style of stroke or border to use: Hidden, Shape Outline, Border, or Double. To learn more about stroke styles, refer to Stroke and Fill Properties. | Stroke and Fill |
Stroke | Details for the chosen stroke. Each Stroke has its own properties depending on the Stroke Style chosen. | Stroke and Fill |
Min. Remainder Height | Minimum distance in points between the bottom of the row that will split onto a new page. The default value of 72 points is equivalent to 1 inch.
Note: This and Min. Split Height are how the table determines when to add another row on to a page, or split the row to a new page. If using rows with a large height (such as those that contain another component, like a chart) you may find that the row is "split" horizontally across multiple pages. Setting this and Min. Split Height to a larger number will help prevent these splits.
| Pagination |
Min. Split Height | Minimum distance in points between the top of the row that will split onto a new page. The default value of 72 points is equivalent to 1 inch. Typically set to the same number as Min. Remainder Height. See the information box on the Min. Remainder Height property above. | Pagination |
Page Break | Data Key or expressions used to determine whether row should force a page break. | Pagination |
Reprint When Wrapped | If true, this row will be reprinted on a new page when its children cross a page boundary. | Pagination |
Stay with Children | The number of children this row must be accompanied by, in the case where some children run off the bottom of a page. | Pagination |
Roll | Number of degrees this shape is rotated clockwise. | Basic Properties |
Scale X | Amount to scale the width of this shape. 1 is scale to 100%. | Basic Properties |
Scale Y | Amount to scale the height of this shape. 1 is scale to 100%. | Basic Properties |
Visible | If true, the shape will be visible. | Basic Properties |
Width | Width of this shape in pixels. | Basic Properties |
Height | Height of this shape in pixels. | Basic Properties |
X | Horizontal distance in pixels between the left edge of this shape and the left edge of the page. | Basic Properties |
Y | Vertical distance in pixels between the upper edge of this shape and the top edge of the page. | Basic Properties |