The following feature is new in Ignition version 8.0.13
Click here to check out the other new features
This function is used in Python Scripting.

Description

Inserts a record into an audit profile.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.util.audit( [action], [actionTarget], [actionValue], [auditProfile], [actor], [actorHost], [originatingSystem], [eventTimestamp], [originatingContext], [statusCode] )

  • Parameters

String action - What happened. [Optional] Default is null.

String actionTarget -  What the action happened to. [Optional] Default is null.

String actionValue -  The value of the action. Default is no value. [optional] 

String auditProfile Where the audit record should be stored. [Optional] Defaults to the project’s audit profile (if specified), or the gateway audit profile if calling in the gateway or perspective scope.

String actor - Who made the change. [Optional] Will be populated automatically if omitted, assuming there is a known user; 

String actorHost The hostname of whoever made the change. [Optional]  Will be populated automatically if omitted.

String, List originatingSystem An even-length list providing additional context to the audit event. Will be appended to the automatically generated list. Typically, the automatically generated context looks like this:  sys:${gatewayName}:\project:${projectName}). So if you provided [“component”, “Joe’sButton”, “field”, “value”], you would get a record with originatingSystem:sys:${gatewayName}:\project:${projectName}:\component:Joe’sButton:\field:valueOr, if a string is provided, this automatic context will not be used and your provided string will be written directly into the originatingSystem column in the audit profile.

Date eventTimestamp - When the event happened. [Optional]  Will be set to the current time if omitted.

Integer originatingContext - What scope the event originated from: 1 means Gateway, 2 means Designer, 4 means Client. [Optional] Will be set automatically if omitted.

Integer statusCode - A quality code to attach to the object. Defaults to 0, indicating no special meaning.

  • Scope

    Gateway, Vision Client, and Perspective Session.

Code Examples
# All of the parameters are optional, so you're free to only provide parameters you're interested in. 
# In the vary least you can always provide just the action you wish to record, allowing the function a chance to look up all of the other parameters automatically
system.util.audit("The user did a thing!")
# Simple example just showing parameter usage. 
myAction = "The button was pressed"
myTarget = "My Button"

system.util.audit(action = myAction , actionTarget = myTarget )
Keywords

system util audit, util.audit