You're currently browsing the Ignition 8.0 docs. Click here to view the latest docs.

This function is used in Python Scripting.

Description

Returns the current state of the matching agents.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Syntax

system.eam.queryAgentStatus(groupIds, agentIds, isConnected)

  • Parameters

List groupIds - A list of groups to restrict the results to. If not specified, all groups will be included.

List agentIds - A list of agent names to restrict the results to. If not specified, all agents will be allowed.

Boolean isConnected - If True, only returns agents that are currently connected. If False, only agents that are considered down will be returned, and if not specified, all agents will be returned.

  • Returns

Dataset - A dataset with columns AgentName, NodeRole, AgentGroup, LastCommunication, IsConnected, IsRunning, RunningState, RunningStateInt, LicenseKey, and Version, where each row is a new agent.

Possible values for RunningState and RunningStateInt are: 0 = Disconnected, 1 = Running, 2 = Warned, 3 = Errored

  •  Scope

Gateway, Vision Client, Perspective Session

Examples
Code Snippet - Querying Agent Status Information
# This script will loop through each row of the dataset and grab out every value from that row and assign it to a matching variable. Those variables can then be used in some way.
results=system.eam.queryAgentStatus()
for row in range(results.rowCount):
	agentName=results.getValueAt(row, "AgentName")
	nodeRole=results.getValueAt(row, "NodeRole")
	agentGroup=results.getValueAt(row, "AgentGroup")
	lastComm=results.getValueAt(row, "LastCommunication")
	isConnected=results.getValueAt(row, "IsConnected")
	isRunning=results.getValueAt(row, "IsRunning")
	runningState=results.getValueAt(row, "RunningState")
	runningStateInt=results.getValueAt(row, "RunningStateInt")
	licenseKey=results.getValueAt(row, "LicenseKey")
	platformVersion=results.getValueAt(row, "Version")
	# Can include some code here to use the variables in some way for each row like printing each variable to the console.
Code Snippet - Querying Agent Status Information
# This script will grab status information from agents called Agent1, Agent2, Agent3, and will then place the data into a table on the same window.
results=system.eam.queryAgentStatus(agentIds=["Agent1", "Agent2", "Agent3"])
event.source.parent.getComponent('Table').data = results
Keywords

system eam queryAgentStatus, eam.queryAgentStatus  

  • No labels