Search

User Manual

GETTING STARTED


MODULES AND PLATFORM


APPENDIX


TUTORIALS & HELPFUL TRICKS


GLOSSARY


STRATEGIC PARTNER LINKS

Sepasoft - MES Modules
Cirrus Link - MQTT Modules

RESOURCES

Inductive University
Ignition Demo Project
Knowledge Base Articles
Forum
IA Support
SDK Documentation
SDK Examples

ALL USER MANUAL VERSIONS

Ignition 8.1
Ignition 7.9
Ignition 7.8

Deprecated Pages

Skip to end of metadata
Go to start of metadata



General

Component Palette Icon:


IULocgo


User, Schedule and Roster Management

Description

The user management panel provides a built-in way to edit User Source users and roles from a Vision Client. 

To make changes to the Gateway's system user source from the Designer or Client, Allow User Admin must be checked in Gateway Settings in the Gateway Config page. 

This component can be run in one of three modes:

Manage Users Mode: In this mode, the component manages all of the users contained in the user source. Users and roles may be added, removed, and edited.

Edit Single Mode: In this mode, the component only edits a single user. Which user is being edited is controlled via the "User Source" and "Username" properties.

Edit Current Mode: In this mode, the user who is currently logged into the project can edit themselves. Obviously, the ability to assign roles is not available in this mode. This can be useful to allow users to alter their own password, adjust their contact information, and update their schedules. 

Warning: Be careful to only expose this component to users who should have the privileges to alter other users. Access to this component in "Manage Users" mode will allow users to edit other users' passwords and roles.

Properties
NameDescriptionProperty TypeScriptingCategory
Border

The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

The border is unaffected by rotation.

Border.borderCommon
Contact Info Editing EnabledIf true, a user's contact info will be editable.boolean.allowContactInfoEditingBehavior
Editing Schedule Available ColorChanges the color of the available times in the schedule. See Color Selector.Color.schedulePreviewAvailableColorAppearance
Editing Schedule Available Text ColorChanges the text color of events on the schedule preview. See Color Selector.Color.eventForegroundAppearance
EnabledIf disabled, a component cannot be used.boolean.componentEnabledCommon
FontFont of the text on this component.Font.fontAppearance
Mode

Affects what mode the user management component runs in.

 Click to see the mode values
ValueDescriptionintValue
Manage UsersAllows edits to all Users and Roles in a single source determined by the User Source property. Default0
Edit CurrentAllows edits to the currently logged in user details.1
Edit SingleAllows edits to a specific user determined by the User Source and Username properties.
2
int.modeBehavior
NameThe name of this component.String.nameCommon
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
Role Assigning EnabledIf true, a user's roles will be editable.boolean.allowRoleAssigningBehavior
Role Management EnabledIf true, role management is available.boolean.allowRoleManagementBehavior
Row HeightAlter the size of the rows in the component's tables.int.rowHeightAppearance
Schedule Adjustments EnabledIf true, a user's schedule adjustments will be editable.boolean.allowScheduleModificationsBehavior
Show Contact Info ColumnControls whether the user table shows the contact info column or not.boolean.columnContactInfoAppearance
Show Name ColumnControls whether the user table shows the name column or not.boolean.columnNameAppearance
Show Roles ColumnControls whether the user table shows the roles column or not.boolean.columnRolesAppearance
Show Schedule ColumnControls whether the user table shows the schedule column or not.boolean.columnScheduleAppearance
Show Username ColumnControls whether the user table shows the username column or not.boolean.columnUsernameAppearance
StylesContains the component's styles.Dataset.stylesAppearance
Table ColorChanges the background color of the tables, User Roles and Role Member lists. Note: When a row is selected it will revert to highlighted.Color.tableBackgroundAppearance
Table Header ColorChanges the background color of the table headers. See Color Selector.Color.tableHeaderBackgroundAppearance
Table Header Text ColorChanges the text color of the table headers. See Color Selector.Color.tableHeaderTextColorAppearance
Table Text ColorChanges the text color of the tables. Note: When a row is selected, it will revert to black. See Color Selector.Color.tableForegroundAppearance
Touchscreen ModeControls when this input component responds if touchscreen mode is enabled.int.touchscreenModeBehavior
User SourceThe user source to manage users in. If blank, uses the project's default user source.String.userProfileBehavior
UsernameThe name of the user being edited. Read-only except when mode is Edit Single, in which case it defines the user to be edited.String.usernameBehavior
Username Editing EnabledIf true, usernames will be editable.boolean.allowUsernameEditingBehavior
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
Window ColorChanges the window background color. See Color Selector.Color.windowBackgroundAppearance
Window Header ColorChanges the window header background color. See Color Selector.Color.windowHeaderBackgroundAppearance
Window Header Save Button Background ColorChanges the window header save button background color. See Color Selector.Color.windowHeaderSaveButtonBackgroundAppearance
Window Header Save Button Text ColorChanges the window header save button text color. See Color Selector.Color.windowHeaderSaveButtonForegroundAppearance
Window Header Text ColorChanges the window header text color. See Color Selector.Color.windowHeaderForegroundAppearance
Window Text ColorChanges the text color of the window. See Color Selector.Color.windowForegroundAppearance
Deprecated Properties
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated
Scripting
Scripting Functions

This component does not have scripting functions associated with it.

Extension Functions
 filterUser
  •  Description

Called for each user loaded into the management table. Return false to hide this user from the management table. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

User Object user - The user object itself. Call user.get('propertyName') to inpsect. Common properties: 'username',' schedule', 'language', user.getRoles() for a list of rolenames.

  • Return

Boolean

  • Scope

Client

 filterRole
  • Description

Called for each role loaded into the management table. Return false to hide this role from the management table. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

String role - The role name.

  • Return

Boolean

  • Scope

Client

 filterSchedule
  •  Description

Called for each schedule loaded into the schedule dropdown in the edit user panel. Return false to hide this schedule from the dropdown. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

String schedule - The schedule name.

  • Return

Boolean

  • Scope

Client

 onCreateUser
  • Description

Called when the add button is pressed in the users table

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the add by calling saveContext.rejectSave('reason')

  • Return

Nothing

  • Scope

Client

 onDeleteUser
  • Description

Called when the delete button is pressed in the users table. This code is executed in the background thread and is called once for each user selected.

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the edit by calling saveContext.rejectSave('reason'). If more than one user is rejected, reasons will be concatenated.

Object user - The user that is trying to be deleted. Call user.get('propertyName') to inspect. Common properties: 'username', 'schedule', 'language'. Call user.getRoles() for a list of rolenames.

  • Return

Nothing

  • Scope

Client

 onSaveUser
  •  Description

Called when the save button is pressed when adding or editing a user. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the edit by calling saveContext.rejectSave('reason').

User Object user - The user that is trying to be saved. Call user.get('propertyName') to inspect. Common properties: 'username', 'schedule','language'. Call user.getRoles() for a list of rolenames.

  • Return

Nothing

  • Scope

Client

 onCreateRole
  • Description

Called when the add button is pressed in the roles table.

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the add by calling saveContext.rejectSave('reason')

  • Return

Nothing

  • Scope

Client

 onDeleteRole
  • Description

Called when the save button is pressed when adding or editing a role. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the edit by calling saveContext.rejectSave('reason'). If more than one role is rejected, reasons will be concatenated.

String name - The role name that is being deleted.

  • Return

Nothing

  • Scope

Client

 onSaveRole
  • Description

Called when the save button is pressed when adding or editing a role. This code is executed in a background thread.

  • Parameters

Component self - A reference to the component that is invoking this function.

Object saveContext - An object that can be used to reject the edit by calling saveContect.rejectSave('reason').

String oldName - The role name before editing. Will be None for a role being added.

String newName - The new name of the edited role.

  • Return

Nothing

  • Scope

Client

Event Handlers
 mouse
 mouseClicked

This event signifies a mouse click on the source component. A mouse click the combination of a mouse press and a mouse release, both of which must have occurred over the source component. Note that this event fires after the pressed and released events have fired.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseEntered

This event fires when the mouse enters the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseExited

This event fires when the mouse leaves the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mousePressed

This event fires when a mouse button is pressed down on the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseReleased

This event fires when a mouse button is released, if that mouse button's press happened over this component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseMotion
 mouseDragged

Fires when the mouse moves over a component after a button has been pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseMoved

Fires when the mouse moves over a component, but no buttons are pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 propertyChange
 propertyChange

Fires whenever a bindable property of the source component changes. This works for standard and custom (dynamic) properties.

.sourceThe component that fired this event
.newValueThe new value that this property changed to.
.oldValueThe value that this property was before it changed. Note that not all components include an accurate oldValue in their events.
.propertyName

The name of the property that changed.

Remember to always filter out these events for the property that you are looking for! Components often have many properties that change.

Examples

There are no examples associated with this component.

  • No labels