General

Component Palette Icon:




Description

A Gantt chart is used for task scheduling. It shows a list of named tasks, each of which have a start date, an end date, and a percentage complete. This allows an easy way to visualize tasks, workflows, and scheduling.

The Gantt chart is configured by populating its Data property. Each row of the dataset represents a task. There should be four columns: the task label, the start date, the end date, and the percentage (0-100) complete.

Properties
NameDescriptionProperty TypeScriptingCategory
Axis FontThe font for axis labels.Font.axisLabelFontAppearance
Border

The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

The border is unaffected by rotation.

Border.borderCommon
Chart TitleAn optional title that will appear at the top of the chart.String.titleAppearance
Complete ColorThe color to draw the amount completed in. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.completeColorAppearance
CursorThe mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize.int.cursorCodeCommon
DataThe data driving the chart.Dataset.dataData
Date Axis TitleA date label to display on the axis title.String.dateAxisTitleAppearance
Incomplete ColorThe color to draw the amount remaining to do in. See Color Selector.Color.incompleteColorAppearance
Mouseover TextThe text that is displayed in the tooltip which pops up on mouseover of this component.String.toolTipTextCommon
NameThe name of this component.String.nameCommon
Plot BackgroundThe background color for the plot. See Color Selector.Color.plotBackgroundAppearance
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
Task Axis Title A task label to display on the Axis Title.String.taskAxisTitleAppearance
Task ColorThe main color to draw tasks. See Color Selector.Color.taskColorAppearance
Tick FontThe font for tick labels.Font.axisTickLabelFontAppearance
Title FontThe font for the optional chart title.Font.titleFontAppearance
Tooltips?Show tooltips on tasks?boolean.tooltipsBehavior
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
Deprecated Properties
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated
Scripting Functions

This component does not have scripting functions associated with it.


Extension Functions

The following feature is new in Ignition version 8.0.16
Click here to check out the other new features

  • Description

Provides an opportunity to perform further chart configuration via scripting.

  • Parameters

Component self- A reference to the component that is invoking this function.

JFreeChart chart- A JFreeChart object. Refer to the JFreeChart documentation for API details.

  • Return

Nothing

Event Handlers

This event signifies a mouse click on the source component. A mouse click the combination of a mouse press and a mouse release, both of which must have occurred over the source component.

This event fires after the pressed and released events have fired.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when the mouse enters the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when the mouse leaves the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when a mouse button is pressed down on the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

This event fires when a mouse button is released, if that mouse button's press happened over this component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires when the mouse moves over a component after a button has been pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires when the mouse moves over a component, but no buttons are pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.

Fires whenever a bindable property of the source component changes. This works for standard and custom (dynamic) properties.

.sourceThe component that fired this event
.newValueThe new value that this property changed to.
.oldValueThe value that this property was before it changed. Note that not all components include an accurate oldValue in their events.
.propertyName

The name of the property that changed.

Remember to always filter out these events for the property that you are looking for! Components often have many properties that change.

Customizers

This component does not have any custom properties.

Examples

This example shows the tasks associated with a construction project on a new house. It is configured by populating the Data Property.  Each row of the dataset includes the start date, end date and a percentage complete for each task. It is a good tool for task scheduling and a easy way to visualize tasks, workflow and scheduling. 


Gantt Chart - Dataset Editor


Gantt Chart - Raw Data

"#NAMES"
"Task Name","Start Date","End Date","Percentage Done"
"#TYPES"
"str","date","date","I"
"#ROWS","12"
"Grading and Site Preparation","2020-05-18 08:00:00.000","2020-05-27 17:00:00.000","100"
"Foundation Construction","2020-05-28 08:00:00.000","2020-06-03 17:00:00.000","100"
"Framing","2020-06-04 08:00:00.000","2020-06-09 17:00:00.000","100"
"Install Windows & Doors","2020-06-10 08:00:00.000","2020-06-16 17:00:00.000","40"
"Roofing","2020-06-10 08:00:00.000","2020-06-26 17:00:00.000","60"
"Electrical","2020-06-22 08:00:00.000","2020-06-30 17:00:00.000","50"
"Plumbing","2020-06-22 08:00:00.000","2020-06-30 17:00:00.000","30"
"Insulation & Drywall","2020-07-01 08:00:00.000","2020-07-07 17:00:00.000","0"
"Interior & Exterior Painting","2020-07-08 08:00:00.000","2020-07-15 17:00:00.000","0"
"Install Cabinetry ","2020-07-13 08:00:00.000","2020-07-17 17:00:00.000","0"
"Carpet & Flooring","2020-07-16 08:00:00.000","2020-07-21 17:00:00.000","0"
"Final Walk Thru","2020-07-22 08:00:00.000","2020-07-22 20:00:00.000","0"