The compass is a component that displays up to three needles at once on a cardinal direction compass. This can be useful for plotting anything that has a cardinal direction, such as the wind direction. 

 Each needle can be one of nine different styles. Use the "Disabled" style to turn off any needle.

Properties
NameDescriptionProperty TypeScriptingCategory
Border

The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Button Border, Field Border, Line Border, and Other Border.

The border is unaffected by rotation.

Border.borderCommon
Center ColorThe center color of the compass. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.Color.centerColorAppearance
CursorThe mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize.int.cursorCodeCommon
Label FontThe font to use for the compass's labels.Font.labelFontAppearance
Mouseover TextThe text that is displayed in the tooltip which pops up on mouseover of this component.String.toolTipTextCommon
NameThe name of this component.String.nameCommon
QualityThe data quality code for any Tag bindings on this component.QualityCode.qualityData
Rose ColorThe background color of the rose. See Color Selector.Color.roseColorAppearance
Rose HighlightThe highlight color of the rose. See Color Selector.Color.roseHighlightColorAppearance
StylesContains the component's styles.Dataset.stylesAppearance
Value 1Value 1 for the compass.double.value1Data
Value 1 ColorThe main color for Value 1's needle. See Color Selector.Color.value1ColorAppearance
Value 1 NeedleThe needle type for this value.int.value1NeedleData
Value 1 OutlineThe outline color for value 1's needle. See Color Selector.Color.value1OutlineColorAppearance
Value 2Value 2 for the compass.double.value2Data
Value 2 ColorThe main color for Value 2's needle. See Color Selector.Color.value2ColorAppearance
Value 2 NeedleThe needle type for this value.int.value2NeedleData
Value 2 OutlineThe outline color for Value 2's needle. See Color Selector.Color.value2OutlineColorAppearance
Value 3Value 3 for the compass.double.value3Data
Value 3 ColorThe main color for Value 3's needle. See Color Selector.Color.value3ColorAppearance
Value 3 NeedleThe needle type for this value.int.value3NeedleData
Value 3 OutlineThe outline color for Value 3's needle. See Color Selector.Color.value3OutlineColorAppearance
VisibleIf disabled, the component will be hidden.boolean.visibleCommon
Deprecated Properties
Data QualityThe data quality code for any Tag bindings on this component.int.dataQualityDeprecated
Scripting
Scripting Functions

This component does not have scripting functions associated with it.

Extension Functions

The following feature is new in Ignition version 8.0.16
Click here to check out the other new features

 configureChart

The following feature is new in Ignition version 8.0.16
Click here to check out the other new features

  • Description

Provides an opportunity to perform further configuration via scripting.

  • Parameters

Component self- A reference to the component that is invoking this function.

JFreeChart chart- A JFreeChart object. Refer to the JFreeChart documentation for API details.

  • Return

Nothing

  • Scope

Client

Event Handlers
 mouse
 mouseClicked

This event signifies a mouse click on the source component. A mouse click the combination of a mouse press and a mouse release, both of which must have occurred over the source component. Note that this event fires after the pressed and released events have fired.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseEntered

This event fires when the mouse enters the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseExited

This event fires when the mouse leaves the space over the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mousePressed

This event fires when a mouse button is pressed down on the source component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseReleased

This event fires when a mouse button is released, if that mouse button's press happened over this component.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseMotion
 mouseDragged

Fires when the mouse moves over a component after a button has been pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 mouseMoved

Fires when the mouse moves over a component, but no buttons are pushed.

.sourceThe component that fired this event
.buttonThe code for the button that caused this event to fire.
.clickCountThe number of mouse clicks associated with this event.
.xThe x-coordinate (with respect to the source component) of this mouse event.
.yThe y-coordinate (with respect to the source component) of this mouse event.
.popupTriggerReturns True (1) if this mouse event is a popup trigger. What constitutes a popup trigger is operating system dependent, which is why this abstraction exists.
.altDownTrue (1) if the Alt key was held down during this event, false (0) otherwise.
.controlDownTrue (1) if the Control key was held down during this event, false (0) otherwise.
.shiftDownTrue (1) if the Shift key was held down during this event, false (0) otherwise.
 propertyChange
 propertyChange

Fires whenever a bindable property of the source component changes. This works for standard and custom (dynamic) properties.

.sourceThe component that fired this event
.newValueThe new value that this property changed to.
.oldValueThe value that this property was before it changed. Note that not all components include an accurate oldValue in their events.
.propertyName

The name of the property that changed.

Remember to always filter out these events for the property that you are looking for! Components often have many properties that change.

Examples

Property NameValue
Center Color0,217,0
Rose Color172,95,0
Label FontTimes New Roman, Bold, 14
Value 1140
Value 1 Color255,0,0
Value 1 NeedlePointer