General

Component Palette Icon:


Description

Suitable for multi-line text display and editing. Will scroll vertically on demand. Horizontal scroll is determined by the "wrap" property. 

Properties

Most Properties have binding options. For more information on Bindings, see Types of Bindings in Perspective.
This section only documents the Props Category of properties. The other Categories are described on the Perspective Component Properties page.

NameDescriptionProperty Type
textText to display.value: string
placeholderText displayed when Text Area is empty.value: string
enabled

If true, user is allowed to alter text.

If the component is disabled, scripts can still run on the component. For example, if you add a script action to the onClick event, the script will fire when the user clicks on the Text Area.

value: boolean

deferUpdates

The following feature is new in Ignition version 8.0.3
Click here to check out the other new features

When true, updates to props.text will be deferred until focus is lost or enter is pressed.

value: boolean

rejectUpdatesWhileFocused

The following feature is new in Ignition version 8.0.3
Click here to check out the other new features

When true, props.text will not accept updates from external sources while focused.

value: boolean

resizeSets whether text is resizable, and if so, in which direction: none, both, horizontal, or vertical.value: string
wrapSpecifies how to wrap text: hard, soft, or off. (Soft wrap is the break resulting from a line wrap or word wrap. Hard wrap is an intentional break, which moves text to the next line, or creates a new paragraph).value: string
styleSets a style for this component. Full menu of style options is available for text, background, margin and padding, border, shape and miscellaneous. You can also specify a style class.object

Perspective Component Events

The Perspective Event Types Reference page describes all the possible component event types for Perspective components. Not all component events support each Perspective component. The Component Events and Actions page shows how to configure events and actions on a Perspective component. Component scripting is handled separately and can be accessed from the Component menubar or by right clicking on the component.

Example

This example shows the Text Area in two states: the top image is with text entered and the bottom image is without text entered. 

PropertyValue
props.text

Data Point 01: xy4, zBeta 3

Data Point 02: xy12, zBeta 45

Notes: Example of how a longer sentence can wrap (or not) around to the next line. Enter was pressed between each of these three lines.

props.placeholderLab Data Entry
props.wrapoff