Component Palette Icon:



Description

The Linear Scale component displays a series of tick marks and labels that represent a range between a minimum value and a maximum value. It also displays indicators that represent a value or range of values, correctly positioned on the linear scale.

The following feature is new in Ignition version 8.0.6
Click here to check out the other new features

Linear Scale component allows floating point tick marks such as 0.25, 0.5, 0.75, 1.25, etc.

Properties

Most Properties have binding options. For more information on Bindings, see Types of Bindings in Perspective.
This section only documents the Props Category of properties. The other Categories are described on the Perspective Component Properties page.

NameDescriptionProperty Type
minValueThe minimum value displayed on the scale.value: numeric
maxValueThe maximum value displayed on the scale.value: numeric
majorTicks

Settings for the major tick marks on the scale.

NameDescriptionProperty Type
span Distance between each tick mark of this type, in pixels. Default is 20.value: numeric
length Length of each tick mark, in pixels. Default is 20.value: numeric
color Color for the major ticks. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.color
stroke Width of each tick mark, in pixels. Default is 1.value: numeric
object
minorTicks

Settings for the minor tick marks on the scale.

NameDescriptionProperty Type
spanDistance between each tick mark of this type, in pixels. Default is 20.value: numeric
lengthLength of each tick mark, in pixels. Default is 20.value: numeric
colorColor for the major ticks. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.color
strokeWidth of each tick mark, in pixels. Default is 1.value: numeric
object
fineTicks

Settings for the fine tick marks on the scale.

NameDescriptionProperty Type
spanDistance between each tick mark of this type, in pixels. Default is 1.value: numeric
lengthLength of each tick mark, in pixels. Default is 5.value: numeric
colorColor for the major ticks. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.color
strokeWidth of each tick mark, in pixels. Default is 1.value: numeric
object
labels

Displays of the numeric values of major tick marks. Options are as follows:

NameDescriptionProperty Type
angleRotation of the numeric labels. Default is 0.value: numeric
style

Sets a style for the label. Full menu of style options is available for text, background, margin and padding, border, shape and miscellaneous. You can also specify a style class.

object
object
indicators

Markers of special significance that can be placed along the scale.

NameDescriptionProperty Type
valueNumeric value along the scale where the indicator is placed or started.value: numeric
labelText to display with the indicator. Default is "High".value: string
labelColorColor of the indicator label. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector.color
labelAngleRotational angle of the indicator label.value: numeric
colorColor of the indicator or the area making up the indicator. See Color Selector.color
strokeIf indicatorStyle is set to line or wedge, stroke is the width (in pixels) of the indicator.value: numeric
opacityOpacity of the indicator. 0 is fully transparent, 1 is fully opaque. value: numeric
lengthLength of the indicator as measured by its x value within the scale. Default is 25.value: numeric
indicatorStyleIndicator style can be set to line, wedge, or range. Line is similar to a tick mark. Wedge displays a triangular shape. Range displays a rectangular range along the scale as measured by the property extent. Default is range.value: string dropdown
extentIf indicatorStyle is set to range, this is the extent along the scale that the indicator is placed. Default is 15.value: numeric
object
mirror Aligns the scale to the opposite side of the component. Default is false.value: boolean
reverseInverts the order of the scale values so min to max is ordered in reverse. Default is false (minimum to max).value: boolean
styleSets a style for this scale. Full menu of style options is available for text, background, margin and padding, border, shape and miscellaneous. You can also specify a style class.object

Perspective Component Events

The Perspective Event Types Reference page describes all the possible component event types for Perspective components. Not all component events support each Perspective component. The Component Events and Actions page shows how to configure events and actions on a Perspective component. Component scripting is handled separately and can be accessed from the Component menubar or by right clicking on the component.

Example

PropertyValue
props.maxValue120
props.minorTicks.span10
props.fineTicks.span

5

props.indicators.0.value95
props.indicators.0.color

#D90000

props.indicators.0.extent25
props.indicators.1.value00
props.indicators.1.indicatorStylerange
props.indicators.1.color#D9D900

props.indicators.1.extent

20
props.indicators.2.value74
props.indicators.2.indicatorStylewedge
props.indicators.2.color#0000D9


  • No labels