Images such as PNGs, JPGs, GIFs, and SVGs can be uploaded to the Image Management Tool and used inside of windows in Ignition. Once uploaded, these images may be used on windows and in templates. The Image Manager tool, available from the Tools > Image Management, provides an interface to upload, download, or select images. 


Bitmap file types are not supported

The Image Manager process does not support bitmap files.

 

The following feature is new in Ignition version 8.0.4
Click here to check out the other new features
SVGs are now supported in the Image Management Tool.

On this page ...


IULocgo


Images (png, jpg, gif)


Using Images in the Designer

Uploading an Image to the Image Management Tool

There are two ways to upload an image into the Image Management tool. Both ways involve having the Image Management tool open. At the top of the Designer in the Menu Bar, select  Tools > Image Management.


Upload on Drag and Drop

Images can simply be dragged and dropped from the local file system into the Image Management window.

Manual Upload

Alternatively, the Image Management window has an Upload button to pass images in. Locate the directory you wish to upload the image. You may use the root folder, or create a new folder to keep your images organized. When ready, click on the Upload Image button.


An Open dialog window will appear. Simply find your image on the local system, and click Open to upload the selected image. 

Downloading Images from the Image Management Tool

Single images, as well as entire directories, may be downloaded from the Image Management tool. This is useful when migrating a project to another Gateway. 

Image downloads can be taken from either the Image Management or Image Browser windows. If at least one folder or image is selected, the Save button  will become enabled. Click the Save button, pick a local directory to save the images to, and click the Save button again. Note that all images and subfolders in the selected folder will be copied to the selected directory.


Exporting and Importing Images in Projects

Uploading an image involves storing the file in the Gateway's internal database. This means that project exports do not contain any referenced images.

When exporting a project for use in another Gateway, it is recommended to also export any images that the project uses, and upload them into the new Gateway at the same directory. Examples of uploading and downloading images can be found on this page. 