Email Alarm Acknowledgement allows operators to acknowledge alarms via a link that is included directly in the email alarm notification. The email alarm acknowledgement process a simple two-step process:

  • The operator receives an email in their inbox alerting them to an alarm(s).
  • The link in the email directs the operator to a landing page describing the alarm(s) where the operator can add notes and acknowledge the alarm(s). 

Once you have an Email Notification Profile created in Ignition, operators can be notified when alarms occur and acknowledge alarms via email. In order to acknowledge alarms in an email, the Two-way Enable option must be set to 'true' in the Email Notification Profile

Email Alarm Acknowledgement Setup

This page assumes an Email Notification Profile, an On-Call Roster containing users with vaild email addresses who will be receiving and acknowledging alarms, and an Alarm Notification Pipeline are configured, including assigning the alarm to a pipeline. You can choose to send one email notification per alarm, or multiple alarms in one email notification using Notification Consolidation.

On this page ...

The following feature is new in Ignition version 8.0.13
Click here to check out the other new features

In version 8.0.13, two new properties were added to the email notification blocks of an Alarm Acknowledgement email:

  • 'Recipient Type' allows you to choose: To, CC and BCC.
  • 'Send Ack' allows you to choose to not send an acknowledgement link on an email notification, even if the notification profile is enabled for two-way authentication. 



Using Email Alarm Acknowledgement

Acknowledging an alarm in an email is super simple! 

  1. Open the the alarm notification email message, and click the link. 



  2. A new window opens describing the alarm. This example shows one email for one alarm. 
  3. If notes are required as in the following example, enter notes about the alarm.
  4. Click the Acknowledge button.




  5. If Notification Consolidation is configured, you can limit the number of email notifications that will be sent, thus, consolidating multiple alarms into one email for operators to acknowledge. 



Check Logs

If you are not receiving any email alarm notifications, check Status > Logs for any error messages. If you are getting errors saying emails are "unreachable," then check your Email Notification Profile.