Contents
Strategic Partner Links
Sepasoft - MES Modules
Cirrus Link - MQTT Modules
Resources
Knowledge Base Articles
Inductive University
Forum
IA Support
SDK Documentation
SDK Examples
The Table component is very powerful and easy to configure. It is very flexible, allowing you to easily display your tabular data in a variety of ways. Important features include:
Basic Usage
The basic usage of the Table is to use a SQL Query binding on its Data property to let the table display data from a database. Often this query will by dynamic or indirect. See the Property Binding section for more information.
Binding to Selected Data
It is common to want to bind other components to values in the selected row of the table. In order to do this safely, you need to write an expression binding that protects against the case when nothing is selected or there are no rows. An expression like this would bind a label to the selected row's value for a column named "ProductCode":
if({Root Container.MyTable.selectedRow} = -1, "n/a", // this is the fail case {Root Container.MyTable.data}[{Root Container.MyTable.selectedRow},"ProductCode"] // this selects from the dataset )
If you're binding to an integer, date, or other non-String type value thats inside a dateset, you'll need to cast the value to the correct type to make the expression parser happy. This binding would cast the selected "Quantity" column to an integer:
if({Root Container.MyTable.selectedRow} = -1, -1, // this is the fail case toInt({Root Container.MyTable.data}[{Root Container.MyTable.selectedRow},"Quantity"]) // this selects from the dataset )
Changing the Column Widths
To change a table's column's widths, simply switch into preview mode and use your mouse to resize the columns, and then switch back to design mode. To ensure that the changes to the column widths appear in the client, right-click on the table to open the table customizer and click OK without clicking anywhere else in the customizer. Clicking anywhere else in the customizer before clicking OK will reset the table column widths.
Editable Table
By setting any column to editable in the Table's customizer, the user will be able to double-click in the cell and edit the data. You can the respond to the resulting cellEdited event with an event handler and persist the data. See the Event Types section for more information.
Exporting to HTML
You can export the table to an HTML file that retain's the table's formatting. To do this, use a script like this: (more about the table's exportHTML() function is here)
# Get a reference to the table and call the exportHTML() function table = event.source.parent.getComponent("Table") table.exportHTML("MyTable.html", "My Table Header", 500)
Exporting to CSV
You can export the table's raw data to a CSV file. To do this, use a script like this: (more about the table's exportCSV() function is here)
# Get a reference to the table and call the exportCSV() finction table = event.source.parent.getComponent("Table") table.exportCSV("MyTable.csv", 1)
Printing
Printing a table is a snap! Simply use the table's built in print function like this: (more about the table's print() function is here)
# Get a reference to the table and call the print() finction table = event.source.parent.getComponent("Table") table.print()
Name | Description | Property Type | Scripting | Category |
---|---|---|---|---|
Antialias | Draw with antialias on? Makes text smoother. | boolean | .antialias | Appearance |
Auto-Resize Mode | Determines how the table resizes the columns. | int | .autoResizeMode | Behavior |
Background Color | The background color of the component. | Color | .background | Appearance |
Background Mode | This mode determines the color that this table's cell's backgrounds will be. | int | .backgroundColorMode | Appearance |
Border | The border surrounding this component. NOTE that the border is unaffected by rotation. | Border | .border | Common |
Column Attributes Data | The dataset describing the column attributes. | Dataset | .columnAttributesData | Data |
Column Selection Allowed | This flag is used in conjunction with the Row Selection Allowed flag to determine whether not whole-rows, whole-columns, or both (single-cells) are selectable. | boolean | .columnSelectionAllowed | Behavior |
Cursor | The mouse cursor to use when hovering over this component. | int | .cursorCode | Common |
Data | The data for this table. | Dataset | .data | Data |
Data Quality | The data quality code for any tag bindings on this component. | int | .dataQuality | Data |
Edit Click Count | The number of clicks required to start editing a cell. | int | .clickCountToStart | Behavior |
Enabled | If disabled, a component cannot be used. | boolean | .componentEnabled | Common |
Font | Font of text on this component. | Font | .font | Appearance |
Foreground Color | The foreground color of the component. | Color | .foreground | Appearance |
Grid Line Color | The color used to draw grid lines. | Color | .gridColor | Appearance |
Header Font | Font of the table's header text. | Font | .headerFont | Appearance |
Header Foreground Color | The foreground color of the table's header. | Color | .headerForeground | Appearance |
Header Visible | Whether or not the table header is visible. | boolean | .headerVisible | Appearance |
Initially Selected Row | The index of the row that should be selected by default when this table's<BR>data is filled in. | int | .initialRowSelection | Behavior |
Name | The name of this component. | String | .name | Common |
Odd Row Background | The color which odd rows will be colored if background mode is 'Alternating'. | Color | .oddBackground | Appearance |
Opaque | If false, backgrounds are not drawn. If true, backgrounds are drawn. | boolean | .opaque | Common |
Properties Loading | The number of properties currently being loaded. (Read only. Usable in bindings and scripting.) | int | .propertiesLoading | Uncategorized |
Resizing Allowed | Whether or not the user is allowed to resize table headers or not. | boolean | .resizingAllowed | Behavior |
Row Height | The height of each row, in pixels. | int | .rowHeight | Appearance |
Row Selection Allowed | This flag is used in conjunction with the Column Selection Allowed flag to determine whether not whole-rows, whole-columns, or both (single-cells) are selectable. | boolean | .rowSelectionAllowed | Behavior |
Selected Column | The index of the first selected column, or -1 if none. | int | .selectedColumn | Data |
Selected Row | The index of the first selected row, or -1 if none. | int | .selectedRow | Data |
Selection Background | The background color of a selected cell. | Color | .selectionBackground | Appearance |
Selection Foreground | The foreground color of a selected cell. | Color | .selectionForeground | Appearance |
Selection Mode | This mode determines if only one row/cell/column can be selected at once, or single or multiple intervals. | int | .selectionMode | Behavior |
Show Horizontal Grid Lines? | Shows horizontal grid lines. | boolean | .showHorizontalLines | Appearance |
Show Vertical Grid Lines? | Shows vertical grid lines. | boolean | .showVerticalLines | Appearance |
TestData | Toggle this property to fill in the table's data with random data. | boolean | .test | Misc |
Touchscreen Mode | Controls when this table component responds if touchscreen mode is enabled. | int | .touchscreenMode | Behavior |
Visible | If disabled, the component will be hidden. | boolean | .visible | Common |
The Table component has a Table customizer to manage column configurations and configure background color mapping. It allows you to customize how you want the table to look to users.
#The following would add a row to the table. #Note that this function takes a list #And that the property types of the list are the same as the table. name = "Motor 1" state = 2 amps = 35 list = [name, state, amps] table = event.source.parent.getComponent('Table') table.addRow(list)