Accessing Parameters and Data Sources
One of the main uses of the Scripting Data Source is to allow for data access and manipulation as the report is being generated, allowing you to replace the original results, or add new additional content.
The syntax for creating or referencing a data key in the Script datasource is described below:
Creating a New Key
To create a new key that the report can use:
data['newKey'] = "This key was generated on the fly!"
The type of data assigned to the key determines where it appears in the Design Panel.
- Simple data types, like strings and integers, will appear as Parameters.
- Datasets will appear as Data Sources.
Report Data

Key Browser

Parameters
Where the 'keyName' is the name of your data key. Thus, reading the value of a parameter, such as the initial StartDate parameter, can be accomplished by using system.date.getYear() and an if-statement.
# Extract the year from the StartDate parameter and compare to 2017.
if system.date.getYear(data['StartDate']) == 2017:
# Do work here if the year lines up.
Of course, we can write back to the key and override it's value:
# This line would override the default StartDate parameter by add adding a day.
data['StartDate'] = system.date.addDays(data['StartDate'], 1)
Additionally, this allows you to expand the Accessing a Parameter's Value example above by creating a new key:
# Extract the year from the StartDate parameter and compare to 2017.
if system.date.getYear(data['StartDate']) == 2017:
# Create a new key and assign it one value if our condition is true...
data['myResults'] = "The year is currently 2017!"
else:
# ...or assign a different value if the condition is false. This way we can always assume the key 'myResults' exists.
data['myResults'] = "What year is it? Not 2017, that's for certain!"
Data Sources
Static CSVs
While uncommon, Static CSVs may be accessed in a Scripting Data Source. The syntax is similar to working with Parameters.
# Take a Static CSV data source, and replicate its contents in a new key.
data['static_data'] = data['Area Data']
Query-Based Data Sources
Reading the contents of a query-based Data Source, such as a SQL Query Data Source or Tag Historian Query, requires the getCoreResults()
function, which returns the results in a standard dataset:
# Query-based Data Sources are slightly different than parameters, so we must use getCoreResults() to extract the data.
rawResults = data['keyName'].getCoreResults()
# getCoreResults() returns a dataset, so we can utilize getValueAt() and rowCount within our scripts.
resultsCount = data['keyName'].getCoreResults().rowCount
When working with data sources, it is unusual to attempt to write back, since datasets are immutable. Instead, the prefered approach is to create a new key with the modified results.
Say we have a query data source named "Area Data" which contains four columns: month, north_area, south_area, and t_stamp. If we need to build a new data source without the t_stamp column, we can use the following code:
# build a header and initialize a pydataset
header = ['month', 'north_area', 'south_area']
filteredDataset = []
# get the results from the Area Data data source
rawDataset = data['Area Data'].getCoreResults()
# build the new pydataset out of only some of the Area Data's data keys
for row in range(rawDataset.rowCount):
valCategory = rawDataset.getValueAt(row,'month')
valNorthArea = rawDataset.getValueAt(row,'north_area')
valSouthArea = rawDataset.getValueAt(row,'south_area')
filteredDataset.append([valCategory,valNorthArea,valSouthArea])
# convert the pydataset to a standard dataset
filteredDataset = system.dataset.toDataSet(header, filteredDataset)
# create a new data source with the filtered results
data['updated Area Data'] = filteredDataset

Nested Queries
What if our 'Area Data' query has a nested query called 'Area Details' that we would like to manipulate in a script? This is useful when using Table Groups.
nested = data['Area Data'].getNestedQueryResults() # Gets results from our parent query
subQuery = nested['Area Details'] # Gets the subquery we want -- there can be more than one
header = ['productName', 'cost', 'triple']
alteredDataset = []
for child in subQuery:
children = child.getCoreResults() # children is a dataset
for row in range(children.rowCount):
valProductName = children.getValueAt(row,'productName')
valCost = children.getValueAt(row,'cost')
valTimesThree = None
if valCost != None:
valTimesThree = 3 * valCost
alteredDataset.append([valProductName,valCost,valTimesThree])
# convert the pydataset to a standard dataset
alteredDataset = system.dataset.toDataSet(header, alteredDataset)
# create a new data source with the altered results
data['Updated Area Details'] = alteredDataset